MB95100A Series
■ SELECT OF OSCILLATION STABILIZATION WAIT TIME (MASK PRODUCT ONLY)
For the MASK product, you can set the mask option when ordering MASK ROM to select the initial value of main
clock oscillation stabilization wait time from among the following four values.
Note that the EVA and FLASH products are fixed their initial value of main clock oscillation stabilization wait time
at the maximum value.
Oscillation stabilization wait time
(22-2) /FCH
(212-2) /FCH
(213-2) /FCH
(214-2) /FCH
Remarks
0.5 µs (at main oscillation clock 4 MHz)
Approx. 1.02 ms (at main oscillation clock 4 MHz)
Approx. 2.05 ms (at main oscillation clock 4 MHz)
Approx. 4.10 ms (at main oscillation clock 4 MHz)
■ PACKAGES AND CORRESPONDING PRODUCTS
Part number
Package
FPT-64P-M03
FPT-64P-M09
BGA-224P-M08
: Available
: Unavailable
MB95107A
MB95F108AS
MB95F108AW
MB95FV100A-101
5