XE2422H REGISTER SETTINGS
SDB Line Voltage Status: SDB is a read only register that stores the value of the loop voltage in two’s
compliment form. The most significant bit, Bit 7, indicates the polarity of the voltage on Tip and
Ring.
Units 1 Volt
Default 00 (Tip and Ring Voltage less than 3 volts)
SE2 Interrupt Enable: SE2 activates the XE2422H Interrupt output. Default = 00
Bit # Definition
7:6: Interrupt Output Control
5:4 /DTR Control
3:2 /DCD
1:0 Reserved
Action
00 = Disabled *
01 = Disabled
10 = Disabled
11 = Interrupt Output Enabled
00 = Disabled *
01 = Disabled
10 = Disabled
11 = /DTR Enabled
00 = /DCD Disabled*
01 = /DCD Enabled
10 = /DCD Disabled
11 = /DCD Disabled
SF1 Power Down Register: SF1 allows the XE2422H to be placed in power down mode. The modem
draws only about 100 microamps in Power down mode. Default = 0C
Bit # Definition
Action
7 Reserved
6 Power Down Mode
0 = Normal Operation
1 = Power Down Selected
5:4 Reserved
3:2 Forced Active
1:0 Reserved
SF3 Loop Current Status: SF3 is a read only register that stores the current value of the loop current.
Units 1.1 Volt
Default 00 (no Loop Current Present)