datasheetbank_Logo
Технический паспорт Поисковая и бесплатно техническое описание Скачать

MPX2100 Просмотр технического описания (PDF) - Motorola => Freescale

Номер в каталоге
Компоненты Описание
Список матч
MPX2100 Datasheet PDF : 10 Pages
1 2 3 4 5 6 7 8 9 10
MOTOROLA
SEMICONDUCTOR TECHNICAL DATA
Order this document
by MPX2100/D
1OCS0ionl0im-cCkophPneianpPsTraeetsmesdpuer&eraCStaeulnriebsroartsed
The MPX2100 and MPX2101 series device is a silicon piezoresistive pressure sensors
providing a highly accurate and linear voltage output — directly proportional to the
applied pressure. The sensor is a single, monolithic silicon diaphragm with the strain
gauge and a thin–film resistor network integrated on–chip. The chip is laser trimmed for
precise span and offset calibration and temperature compensation.
Features
Temperature Compensated Over 0°C to + 85°C
Unique Silicon Shear Stress Strain Gauge
Easy to Use Chip Carrier Package Options
Available in Absolute, Differential and Gauge Configurations
Ratiometric to Supply Voltage
• ± 0.25% Linearity (MPX2100D)
Application Examples
Pump/Motor Controllers
Robotics
Level Indicators
Medical Diagnostics
Pressure Switching
Barometers
Altimeters
Figure 1 illustrates a block diagram of the internal circuitry on the stand–alone
pressure sensor chip.
VS
3
X–ducer
SENSING
ELEMENT
THIN FILM
TEMPERATURE
COMPENSATION
AND
CALIBRATION
CIRCUITRY
2
Vout+
4 Vout–
1
GND
Figure 1. Temperature Compensated Pressure Sensor Schematic
VOLTAGE OUTPUT versus APPLIED DIFFERENTIAL PRESSURE
The differential voltage output of the X–ducer is directly proportional to the differential
pressure applied.
The absolute sensor has a built–in reference vacuum. The output voltage will decrease
as vacuum, relative to ambient, is drawn on the pressure (P1) side.
The output voltage of the differential or gauge sensor increases with increasing
pressure applied to the pressure (P1) side relative to the vacuum (P2) side. Similarly,
output voltage increases as increasing vacuum is applied to the vacuum (P2) side
relative to the pressure (P1) side.
Preferred devices are Motorola recommended choices for future use and best overall value.
Senseon and X–ducer are trademarks of Motorola, Inc.
REV 6
©MMoottoororolal,aInSc.e1n9s97or Device Data
MMSPPEXXR22I11E00S01
Motorola Preferred Device
0 to 100 kPa (0 to 14.5 psi)
40 mV FULL SCALE SPAN
(TYPICAL)
BASIC CHIP
CARRIER ELEMENT
CASE 344–15, STYLE 1
DIFFERENTIAL
PORT OPTION
CASE 344C–01, STYLE 1
NOTE: Pin 1 is the notched pin.
PIN NUMBER
1
Gnd
3
VS
2
+Vout
4 –Vout
1

Share Link: 