1 2 3 4 5 6 7 8 9 10 Next Last
Dual, High-Efficiency, Step-Down
Controller with High Impedance in Shutdown
ELECTRICAL CHARACTERISTICS (continued)
(Circuit of Figure 1, VDD = VCC = 5V, SKIP = AGND, V+ = 15V, TA = 0°C to +85°C, typical values are at +25°C, unless otherwise
noted.)
PARAMETER
On-Time, Side 1
On-Time, Side 2
On-Time Tracking
Minimum Off-Time
Quiescent Supply Current (VCC)
Quiescent Supply Current (VDD)
Quiescent Supply Current (V+)
Shutdown Supply Current (VCC)
Shutdown Supply Current (VDD)
Shutdown Supply Current (V+)
Reference Voltage
Reference Load Regulation
REF Sink Current
REF Fault Lockout Voltage
Overvoltage Trip Threshold
(Fixed-Threshold Mode)
SYMBOL
CONDITIONS
tON1
tON2
tOFF
ICC
IDD
I+
V+ = 24V,
VOUT1 = 2V
(Note 3)
V+ = 24V,
VOUT2 = 2V
(Note 3)
TON = AGND
TON = REF
TON = float
TON = VCC
TON = AGND
TON = REF
TON = float
TON = VCC
On-time 2 with
respect to on-
time 1
(Note 3)
TON = AGND
TON = REF
TON = float
TON = VCC
(Note 3)
FB_ forced above the regulation point
FB_ forced above the regulation point
Measured at V+
ON1 = ON2 = AGND, OVP = VCC
ON1 = ON2 = AGND
ON1 = ON2 = AGND, measured at V+,
VCC = AGND or 5V
VREF
VCC = 4.5V to 5.5V, no external REF load
IREF = 0 to 50µA
REF in regulation
Falling edge, hysteresis = 40mV
OVP = AGND, with respect to error-
comparator trip threshold
MIN TYP MAX UNITS
120
137
153
153
174
195
ns
222
247
272
316
353
390
160
182
204
205
234
263
ns
301
336
371
432
483
534
125
135
145
125
135
145
%
125
135
145
125
135
145
400 500
ns
1100 1500 µA
<1
5
µA
25
70
µA
<1
5
µA
<1
5
µA
<1
5
µA
1.98
2
2.02
V
0.01
V
10
µA
1.6
V
112
114
117
%
Overvoltage Comparator Offset
(Adjustable-Threshold Mode)
1V < VOVP < 1.8V, external feedback,
measured at FB_ with respect to VOVP
1V < VOVP < 1.8V, internal feedback,
measured at OUT_ with respect to OUT_
regulation point
-28
0
+28
mV
-3.5
0
+3.5
%
OVP Input Leakage Current
Overvoltage Fault Propagation
Delay
1V < VOVP < 1.8V
FB_ forced 2% above trip threshold
-100
<1 +100 nA
1.5
µs
Output Undervoltage Threshold
UVP = VCC, with respect to error-comparator
trip threshold
65
70
75
%
Output Undervoltage Protection
Blanking Time
From ON_ signal going high
10
30
ms