1µA, 2Mbps, Low-Voltage Level
Translators in SC70 and µDFN
ELECTRICAL CHARACTERISTICS (continued)
(VCC = +2.5V to +5.5V, VL = +1.6V to +5.5V (Note 1), GND = 0; I/O VL, I/O VCC unconnected; TA = -40°C to +85°C, unless otherwise
noted. Typical values are at TA = +25°C.) (Note 2)
PARAMETER
SYMBOL
CONDITIONS
MIN TYP MAX UNITS
LOW-to-HIGH Transition
Propagation Delay
Device-to-Device Skew
(Driving I/O VL)
CLOAD = 10pF, data rate = 2Mbps (Note 3)
5
CLOAD = 50pF, data rate = 1Mbps
CLOAD = 30pF, data rate = 500kbps,
open-drain drive
8
ns
80
HIGH-to-LOW Transition
Propagation Delay
Device-to-Device Skew
(Driving I/O VCC)
CLOAD = 10pF, data rate = 2Mbps (Note 3)
2
CLOAD = 50pF, data rate = 1Mbps
CLOAD = 30pF, data rate = 500kbps,
open-drain drive
4
ns
5
LOW-to-HIGH Transition
Propagation Delay
Device-to-Device Skew
(Driving I/O VCC)
CLOAD = 10pF, data rate = 2Mbps (Note 3)
7
CLOAD = 50pF, data rate = 1Mbps
CLOAD = 30pF, data rate = 500kbps,
open-drain drive
8
ns
50
Maximum Data Rate
CLOAD = 10pF (Note 5)
CLOAD = 50pF
CLOAD = 30pF, open-drain drive
2
3
1
2
0.5
1
Mbps
Note 1: VL must always be less than or equal to VCC.
Note 2: All units are 100% production tested at TA = +25°C. Limits over the operating temperature range are guaranteed by design
and not production tested.
Note 3: Tested only at worst case: VCC = +2.5V, VL = +1.6V.
Note 4: 10% to 90%.
Note 5: Guaranteed by correlation to CLOAD = 50pF.