TIS
Up to 5 static intruders may be simulated relative to the A/C (UUT).
TIS-B:
The user enters the A/C (UUT) LAT/LONG and heading.
Up to 5 static intruders may be simulated relative to the A/C (UUT).
General
Radiated Testing:
The IFR 6015 is supplied with a lightweight fully sealed directional
antenna that may be test set mounted, hand held or tripod mounted.
Direct Connect Testing:
The IFR 6015 may be directly connected to the UUT via a supplied
RF coax cable via the RF I/O port.
Transit Case:
The IFR 6015 is supplied in a rugged plastic transit case which pro-
vides stowage for the test set, directional antenna, RF coax cable,
antenna shield, breakout box, and power supply/charger.
SPECIFICATION
DME MODE SPECIFICATIONS
SIGNAL GENERATOR
A 5-minute warm-up period is required for all specifications.
OUTPUT FREQUENCY
REPLY FREQUENCY
Range
962 to 1213 MHz
Accuracy
± 10 kHz
OUTPUT LEVEL
ANTENNA PORT
Range
-67 to -2 dBm at Antenna port
Resolution
1 dB
Accuracy
± 2 dB
Distance to UUT antenna
6 to 300 ft with supplied antenna
RF I/O PORT
Range
-115 to -47 dBm
Resolution
1 dB
Accuracy
-95 dBm to –47 dBm
± 1 dB
Accuracy
-115 dBm to <-95 dBm ± 2 dB
REPLY PULSE SPACING
P1 to P2
12 µs ± 100 ns (X Channel) @ 50% peak
P1 to P2
30 µs ± 100 ns (Y Channel) @ 50% peak
w w w. a e r o f l ex . c o m For the very latest specifications visit