IDT74LVCH16652
3.3V CMOS 16-BIT BUS TRANSCEIVER AND REGISTER
INDUSTRIAL TEMPERATURE RANGE
FUNCTION TABLE(1)
xOEAB xOEBA
Inputs
xCLKAB xCLKBA
xSAB
xSBA
Data I/O(2)
xAx
xBx
Operation or Function
L
H
H or L
H or L
X
X
Input
Input
Isolation
L
H
X
X
Input
Input
Store A and B Data
X
H
H or L
X
X
Input
Unspecified(3)
Store A, hold B
H
H
X(3)
X
Input
Output
Store A in both registers
L
X
H or L
X
X
Unspecified(3)
Input
Hold A, store B
L
L
X
X(3)
Output
Input
Store B in both registers
L
L
X
X
X
L
Output
Input
Real time B data to A bus
L
L
X
H or L
X
H
H
X
X
L
H
H
H or L
X
H
H
Output
X
Input
X
Input
Input
Output
Output
Stored B data to A bus
Real time A data to B bus
Stored A data to B bus
H
L
H or L
H or L
H
H
Output
Output
Stored A data to B Bus and
Stored B data to A bus
NOTES:
1. H = HIGH Voltage Level
L = LOW Voltage Level
X = Don't Care
= LOW-to-HIGH Transition
2. The data output functions may be enabled or disabled by various signals at the xOEAB or xOEBA inputs. Data input functions are always enabled, i.e. data at the bus pins will
be stored on every LOW-to-HIGH transition on the clock inputs.
3. Select control = L: clocks can occur simultaneously.
Select control = H: clocks must be staggered to load both registers.
DC ELECTRICAL CHARACTERISTICS OVER OPERATING RANGE
Following Conditions Apply Unless Otherwise Specified:
Operating Condition: TA = –40°C to +85°C
Symbol
Parameter
Test Conditions
Min. Typ.(1)
Max.
Unit
VIH
Input HIGH Voltage Level
VCC = 2.3V to 2.7V
1.7
V
VCC = 2.7V to 3.6V
2
VIL
Input LOW Voltage Level
VCC = 2.3V to 2.7V
VCC = 2.7V to 3.6V
0.7
V
0.8
IIH
Input Leakage Current
IIL
VCC = 3.6V
VI = 0 to 5.5V
±5
µA
IOZH
High Impedance Output Current VCC = 3.6V
VO = 0 to 5.5V
±10
µA
IOZL
(3-State Output pins)
IOFF
Input/Output Power Off Leakage VCC = 0V, VIN or VO 5.5V
±50
µA
VIK
Clamp Diode Voltage
VCC = 2.3V, IIN = –18mA
–0.7
–1.2
V
VH
Input Hysteresis
VCC = 3.3V
ICCL
Quiescent Power Supply Current VCC = 3.6V
ICCH
ICCZ
VIN = GND or VCC
3.6 VIN 5.5V(2)
ICC
Quiescent Power Supply Current One input at VCC - 0.6V, other inputs at VCC or GND
Variation
100
mV
10
µA
10
500
µA