datasheetbank_Logo
Технический паспорт Поисковая и бесплатно техническое описание Скачать

XE2814 Просмотр технического описания (PDF) - Xecom

Номер в каталоге
Компоненты Описание
Список матч
XE2814 Datasheet PDF : 19 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
AT Command List (continued)
&Qn - Line Connection
n=0 Direct mode (no data buffering)*
n=5 Use Error Correction
n=6 Normal Mode (Speed buffering)
&Sn - DSR Operation
n=0 DSR always active*
n=1 DSR in accordance with V.25.
&Tn - Test Modes
n=0 Exit test mode
n=1 Local analog loopback
n=3 Initiate local digital loopback
n=4 Respond to remote loop request*
n=5 Deny remote loop request
n=6 Intiate a Remote Digital loopback
n=7 Remote digital loopback w self-test
n=8 Local analog loopback w self-test
&Vn - View Configuration Profiles
n=0 View active profile & user profile 0*
n=1 View active profile & user profile 1
&Wn - Store Active Profile
n=0 Store active profile as profile 0*
n=1 Store active profile as profile 1
&Yn - Recall Stored Profile
n=0 Recall profile 0 on power-up*
n=1 Recall profile 1 on power-up
&Zn=x - Store telephone number "x" in
memory location "n"
%En - Line Quality Monitor/Auto Retrain
n=0 Disabled
n=1 Enabled
n=2 Line quality, fallback, fall forward
%L - Read Recevied Signal Level
%Q - Read Line Signal Quality
\An - MNP Block Size
n=0 Maximum 64 characters
n=1 Maximum 128 characters
n=2 Maximum 192 characters
n=3 Maximum 256 characters*
\Bn - Transmit Break n x 100 msec
\Gn - Modem to Modem Flow Control
n=0 No modem to modem flow control*
n=1 XON/XOFF flow control
\Jn - DTE Rate Adjust
n=0 Serial port speed independent of
link speed*
n=1 Serial port rate automatically
changed to link speed*
\Kn - Break control
Break received from host with
Reliable link established.
n=0 Enter on-line command mode; do
not transmit break
n=1 Purge buffers, immediately
transmit break
n=2 Same as n=0
n=3 Immediately send break
n=4 same as n=0
n=5 Send break in sequence with data*
Break received from host with Direct
link established.
n=0 Immediately transmit break, then
enter on-line command mode
n=1 Immediately send break
n=2 Enter command mode but do not
transmit break signal
n=3 same as n=1
n=4 same as n=0
n=5 same as n=1*
8/XECOM
XE2814

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]