M52347SP/FP
SYNC SIGNAL PROCESSOR
3) Polarity detection and non-input detection (pins 7 and 8 )
External capacitance is required as a filter pin to detect polarity
and non-input. As the value is larger, the ripple is smaller and
less malfunction occurs. However, the response speed for
detection is lower. A sufficient external capacitance is 0.05 µF
with input of 15 kHz and 10 uF with input of 60 kHz. However,
check the frequency of the input signal in use and the filter pin
waveform with the duty ratio conditions, and then check that the
value is 3.1V or more (2.8V in capability) with positive polarity
input and 1.9V or less (2.2V in capability) with negative polarity
input.
4) V S/S IN (pin 11 )
Input a signal of having externally integrated composite sync for
V sync separation.
Composite sync input into pin 6 is output to pin 12 . Output at 12
is externally integrated and is input into pin 11 for V sync
separation. With the waveform at pin 11 , check that the H
element has been fully dropped.
The threshold levels of sync separation, given hysteresis, are
3.5V and 1.8V.
Input waveform at
pin 6
when COMP/H only is input or when both COMP/H and GREEN
are input.
8
6
4
R=10k
2
R=4.3k
0
10
100
1000
Clamp Timing Capacitance at Pin 20 (pF)
3. Sampling Pulse from VD Portion
V TIME GATE SW (Pin 10 )
Whether to output the pulse of VD portion from pins 14 and 15
can be selected. When pin 10 is "H" or OPEN, pulse of the VD
portion is output. When pin 10 is "L", the pulse of the VD portion
is not output.
Waveform at
pin 11
Output waveform at
pin 13
VTH=3.5V
VTH=1.8V
Output at pin 14 when the pin 10 is "H" or OPEN
2. Clamp Pulse
1) Clamp pulse width
CLAMP TIMING (Pin 20 )
The clamp pulse width is determined by the external resistance
and the capacitance. As the resistance value and capacitance
value are larger, the clamp pulse width is wider.
The time constant is determined by the current flowing out of pin
20 and the capacitance value of the timing pin. The flow current
at pin 20 is determined by the pin voltage and external resistance
value. When the external resistance is 4.3 (that is 700 uA) and
the external capacitance is 220 pF, the pulse width is 0.4 usec.
2) Clamp pulse position
CLAMP SW (pin 3 )
When pin 3 is "M" or "L", fixing a higher-priority signal to the
trailing edge results in occurrence of a clamp pulse. When pin 3
is 'H", and only GREEN is input, clamp pulse occurs at the
trailing edge. A clamp pulse also occurs at the leading edge
VD portion
Output at pin 14 when pin 10 is "L"
Output at pin 15 when pin 10 is "H" or OPEN
VD portion
Output at pin 15 when pin 10 is "L"