RECOMMENDED OPERATING CONDITIONS (DGND = 0V; all voltages with respect to ground)
Parameter
Symbol Min
Typ
Max
Unit
DC Power Supplies:
Positive Digital
VD+
4.75
5.0
VA+
V
Positive Analog
VA+
4.75
5.0
5.25
V
Negative Analog
VA
-4.75
-5.0
-5.25
V
(VD+) - (VA+) (Note 3) -
-0.3
-
0.0
V
Ambient Operating Temperature
TA
0
25
70
°C
Notes: 3. Applying power to VD+ prior to VA+ creates a SCR latch-up condition. Refer to Figure 2 for the
recommended power connections.
ABSOLUTE MAXIMUM RATINGS (AGND, DGND = 0V, all voltages with respect to ground.)
Parameter
DC Power Supplies:
Positive Digital
Positive Analog
Negative Analog
Input Current, Any Pin Except Supply
Digital Input Voltage
Ambient Operating Temperature (power applied)
Storage Temperature
Symbol
Min
VD+
-0.3
VA+
-0.3
VA-
0.3
Iin
-
VIND
-0.3
TA
-55
TSTG
-65
Max
Unit
(VA+)+ 0.3
V
6.0
V
-6.0
V
±10
mA
(VA+) + 0.3
V
+125
°C
+150
°C
4