AT25080/160/320/640
AC Characteristics (Continued)
Applicable over recommended operating range from TA = -40°C to +85°C, VCC = As Specified,
CL = 1 TTL Gate and 100 pF (unless otherwise noted).
Symbol
Parameter
Voltage
Min
Max
tLZ
Hold to Output Low Z
4.5 - 5.5
0
100
2.7 - 5.5
0
100
1.8 - 3.6
0
100
4.5 - 5.5
100
tHZ
Hold to Output High Z
2.7 - 5.5
100
1.8 - 3.6
100
tDIS
Output Disable Time
4.5 - 5.5
2.7 - 5.5
1.8 - 3.6
250
250
1000
4.5 - 5.5
5
tWC
Write Cycle Time
2.7 - 5.5
10
1.8 - 3.6
20
Endurance(1)
5.0V, 25°C, Page Mode
1M
Note: 1. This parameter is characterized and is not 100% tested.
Units
ns
ns
ns
ms
Write Cycles
5