VT5F9MN0006/07
• Temperature characteristic. Measure at 0 to 60°C:
check for variation from initial value.
– Video modulation factor, temperature stability ±10%
– Video carrier, temperature stability ±100 kHz
– Audio modulation factor, temperature stability ±12%
– Audio carrier, temperature stability ±15 kHz
– Video output level temperature stability 66 ±3 dB
– Audio output level difference 50 ±4 dB
– Synchronous level, temperature stability
V/S = 7 ±0.5/3 ±0.5
– Differential gain, temperature stability 15% (MAX.)
– Differential phase, temperature stability 15° (MAX.)
• Overall picture and total quality
– Operation shall be problem-free. This paragraph is
subject to sensory tests; therefore, any discrepan-
cy arising between the parties concerned regarding
final judgment shall be settled by mutual consent.
(Limit standards shall be specified as needed.)
• Power source
– Input voltage 5 VDC ±0.2 +B (MOD)
– Allowable ripple voltage: 50 mVp-p MAX.
– Current consumption 30 mA (MAX.), 20 mA (TYP.)
Booster
• Insertion loss – ANT IN TV OUT 6.5 dB (MAX.)
– Measure at 55 MHz to 890 MHz
• Distribution loss –ANT IN TUN OUT 6 dB (MAX.)
– Measure at 55 MHz to 890 MHz
• Isolation 60 dB (MIN.), fs, fp
• VSWR, measure at 55 MHz to 890 MHz
– ANT IN 4 (MAX.)
– TUN OUT 3 (MAX.)
– TV OUT
– MOD OFF 4 (MAX.)
– MOD ON 3 (MAX.) fs, fp
• Cross Modulation (dBµ). Input level = 100 dBµ (at
50 terminal)
– f1 = 183 MHz, f2 = 189 MHz, f(IM) = 177 MHz
– 55 (MIN.)
– f1 = 183 MHz, f2 = 189 MHz, f(IM) = 195 MHz
– 55 (MIN.)
• Switching operation
– ANT IN TV OUT
– Ground +B terminal
– MOD OUT TV OUT
– When +5 V is applied across +B terminal
Durability Test
• Vibration test
– Apply vibration of 2 mm full amplitude, 1,500
times/minute from three directions for 15 minutes
each: there shall be no looseness, etc., and all
performance requirements shall be satisfied.
• Impact test
– Apply a 70 G impact using an impact tester; no
damaged parts or looseness shall be observed,
and performance shall not be remarkably affected.
• Moisture resistance
– Test samples shall be left in an environment with
temperature at 40°C ±5°C and relative humidity at
90 +0, -3%, for 500 hours, then left at normal tem-
perature and humidity for 40 minutes. The unit
shall then operate normally without malfunction.
• High temperature resistance
– Test samples shall be left in a 70°C ±2°C bath for
500 hours, then at normal temperature and hu-
midity for 40 minutes. The unit shall then operate
normally without malfunction.
• Low temperature resistance
– Test samples shall be left in a -20°C ±2°C bath
for 500 hours, then at normal temperature and
humidity for 40 minutes. The unit shall then oper-
ate normally without malfunction.
• Thermal shock resistance
– 10 test cycles shall be conducted under the fol-
lowing conditions (see Figure 2) and test samples
shall then be placed in a normal temperature and
humidity atmosphere, cleared of excess water,
left for 40 minutes. Subsequent operation shall be
trouble-free.
Operating Conditions
• Operating guarantee conditions
– Operation shall be trouble-free under ±0°C to
60°C and 85% RH MAX.
• Storage conditions
– Temperature -10°C to 70°C
– Humidity 90% RH (MAX.)
Electrostatic Test
• Electrostatic test (15 kV (+) and (–) polarities, 10
times each) shall be conducted on ANT IN and TV
OUT terminals. Subsequent operation shall be trou-
ble-free (C = 200 pF, R = 500 ).
• Antenna in/Tuner out
– Yes/Yes
NORMAL
TEMPERATURE
70°C
30 MINUTES
30 MINUTES
-20°C
WITHIN
1 MINUTE
MOD20-2
Figure 2. Thermal Shock Resistance
RF Data Sheet