Specifications CD4095BMS, CD4096BMS
TABLE 4. POST IRRADIATION ELECTRICAL PERFORMANCE CHARACTERISTICS
LIMITS
PARAMETER
SYMBOL
CONDITIONS
N Threshold Voltage
Delta
VTN VDD = 10V, ISS = -10µA
P Threshold Voltage
VTP VSS = 0V, IDD = 10µA
P Threshold Voltage
Delta
VTP VSS = 0V, IDD = 10µA
Functional
F
VDD = 18V, VIN = VDD or GND
VDD = 3V, VIN = VDD or GND
Propagation Delay Time
TPHL VDD = 5V
TPLH
NOTES: 1. All voltages referenced to device GND.
2. CL = 50pF, RL = 200K, Input TR, TF < 20ns.
NOTES
1, 4
TEMPERATURE MIN
+25oC
-
1, 4
+25oC
0.2
1, 4
+25oC
-
1
1, 2, 3, 4
+25oC
+25oC
VOH >
VDD/2
-
3. See Table 2 for +25oC limit.
4. Read and Record
MAX
±1
2.8
±1
VOL <
VDD/2
1.35 x
+25oC
Limit
UNITS
V
V
V
V
ns
TABLE 5. BURN-IN AND LIFE TEST DELTA PARAMETERS +25oC
PARAMETER
SYMBOL
DELTA LIMIT
Supply Current - MSI-1
IDD
± 0.2µA
Output Current (Sink)
IOL5
± 20% x Pre-Test Reading
Output Current (Source)
IOH5A
± 20% x Pre-Test Reading
TABLE 6. APPLICABLE SUBGROUPS
CONFORMANCE GROUP
MIL-STD-883
METHOD
GROUP A SUBGROUPS
Initial Test (Pre Burn-In)
100% 5004
1, 7, 9
Interim Test 1 (Post Burn-In)
100% 5004
1, 7, 9
Interim Test 2 (Post Burn-In)
100% 5004
1, 7, 9
PDA (Note 1)
100% 5004
1, 7, 9, Deltas
Interim Test 3 (Post Burn-In)
100% 5004
1, 7, 9
PDA (Note 1)
100% 5004
1, 7, 9, Deltas
Final Test
100% 5004
2, 3, 8A, 8B, 10, 11
Group A
Sample 5005
1, 2, 3, 7, 8A, 8B, 9, 10, 11
Group B
Subgroup B-5
Sample 5005
1, 2, 3, 7, 8A, 8B, 9, 10, 11, Deltas
Subgroup B-6
Sample 5005
1, 7, 9
Group D
Sample 5005
1, 2, 3, 8A, 8B, 9
NOTE: 1. 5% Parameteric, 3% Functional; Cumulative for Static 1 and 2.
READ AND RECORD
IDD, IOL5, IOH5A
IDD, IOL5, IOH5A
IDD, IOL5, IOH5A
IDD, IOL5, IOH5A
Subgroups 1, 2, 3, 9, 10, 11
Subgroups 1, 2 3
CONFORMANCE GROUPS
Group E Subgroup 2
TABLE 7. TOTAL DOSE IRRADIATION
MIL-STD-883
METHOD
TEST
PRE-IRRAD
POST-IRRAD
5005
1, 7, 9
Table 4
READ AND RECORD
PRE-IRRAD
POST-IRRAD
1, 9
Table 4