THEORY OF OPERATION
In the ADC150 block diagram (see Figure 1), Vhi
and Vlow are the inputs. Both are buffered and fed
into a differential, voltage controlled, single output
current source. This current is added to the
reference current at the input of the op amp
integrator. The output of the integrator is fed into
a Schmitt trigger, which in turn, is fed into the
ADC's timing control circuitry. When the
integrator output actuates the Schmitt trigger, the
timing circuit changes the direction of the
reference current source and the integrator
begins integrating in the opposite direction. This
continues until the Schmitt trigger is actuated
again by the integrator and reverses the direction
of the reference current.
The equation for integration times are:
VXC
Tp= I ref + I inp
VXC
Tm=
-I ref + I inp
V = Voltage
C= Integration Capacitor Value
I ref = Reference Current
I inp = Input Current
Resolving these equations produces:
I inp = I ref Tp - Tm
Tp + Tm
Tp = Time Positive
Tm = Time Negative
The timing control circuitry governs the counters that
measure the integration time in both directions.
The ADC150's on-board microprocessor is used to
calculate the results of the integration equation and
perform error corrections. Note that the µP
automatically performs an auto zero function at start-
up, but it is recommended to achieve maximum
accuracy, that an auto zero be performed again after
the ADC150 is fully warmed up.
When the µP detects a convert signal, it lowers the
status lines to indicate that the ADC is involved in a
conversion. When it detects a change in slope
direction, the µP will collect the counts for the
integration time. When sufficient counts have been
collected, the µP performs the calculations described
above.
When the calculations are complete, the µP places
the most significant byte in the output buffer and
raises the S0 flag. When another pulse is placed on
the convert line, the middle byte is placed on the
output, the S0 flag is lowered and the S1 flag raised.
When the last pulse is placed in the convert line, the
least significant byte is placed in the output buffer and
both status flags are high indicating that the ADC150
is ready for another conversion.
Status line summary:
S1 S0
0 0 Conversion in progress.
0 1 Conversion complete. MSB in output.
1 0 Middle byte in output register.
1 1 LSB in output. Ready for next conversion.
Vhi
Auto
Zero
Switch
Vlow
Differential
Voltage Controlled
Current Source
Bidirectional
Reference
Current Source
Schmitt
Trigger
Current
Directional
Switch
+15V
-15V
ï ï Data
Output
Output
Buffer
Microprocessor
ï Timing
Control
and
Counter
Clock
Output Enable
FIGURE 1. BLOCK DIAGRAM
Auto Convert Status
Zero
Lines
ADC150DS REV. F MAR 00