LTC1659
ELECTRICAL CHARACTERISTICS The denotes the specifications which apply over the full operating
temperature range, otherwise specifications are at TA = 25°C. VCC = 2.7V to 5.5V, VOUT unloaded, REF ≤ VCC, TA = TMIN to TMAX
unless otherwise noted.
SYMBOL PARAMETER
CONDITIONS
MIN TYP MAX UNITS
Switching (VCC = 4.5V to 5.5V
t1
DIN Valid to CLK Setup
t2
DIN Valid to CLK Hold
t3
CLK High Time
t4
CLK Low Time
t5
CS/LD Pulse Width
t6
LSB CLK to CS/LD
t7
CS/LD Low to CLK
t8
DOUT Output Delay
t9
CLK Low to CS/LD Low
Switching (VCC = 2.7V to 5.5V)
t1
DIN Valid to CLK Setup
t2
DIN Valid to CLK Hold
t3
CLK High Time
t4
CLK Low Time
t5
CS/LD Pulse Width
t6
LSB CLK to CS/LD
t7
CS/LD Low to CLK
t8
DOUT Output Delay
t9
CLK Low to CS/LD Low
(Note 7)
(Note 7)
(Note 7)
(Note 7)
(Note 7)
CLOAD = 15pF
(Note 7)
(Note 7)
(Note 7)
(Note 7)
(Note 7)
(Note 7)
CLOAD = 15pF
(Note 7)
40
0
40
40
50
40
20
5
20
60
0
60
60
80
60
30
10
30
ns
ns
ns
ns
ns
ns
ns
150
ns
ns
ns
ns
ns
ns
ns
ns
ns
220
ns
ns
Note 1: Stresses beyond those listed under Absolute Maximum Ratings
may cause permanent damage to the device. Exposure to any Absolute
Maximum Rating condition for extended periods may affect device
reliability and lifetime.
Note 2: Nonlinearity is defined from code 20 to code 4095 (full scale). See
Applications Information.
Note 3: Load is 5kΩ in parallel with 100pF.
Note 4: DAC switched between all 1s and the code corresponding to VOS
for the part.
Note 5: Digital inputs at 0V or VCC.
Note 6: VOUT can only swing from (GND + |VOS|) to (VCC – |VOS|) when
output is unloaded.
Note 7: Guaranteed by design, not subject to test.
1659fa