Dimensions DHR-C5 (in mm. 1 mm = 0.0394 inch)
25
70
60
2 2.2 8
6 .80
90
4
15
7
6
78
Connections
• Wires up to 2 mm ∅
•DFHeRm-aCle5/c1o0nnector provided (screw terminals)
DHR
24 VDC Power
(+)
(-)
Output Connector
1(Vcc) 2(NC) 3(Vout) 4(GND)
10k
(-)
(+)
Load
(Controller, meter etc)
+24VDC
Is
OUT
Ip
GND
Mechanical characteristics
• General tolerance
±1 mm
• Primary aperture
∅ 32.0 mm
• Panel mounting
4 holes ∅ 4.6 mm
• Distance between holes
70.0 mm & 78 mm
(see above dimensions)
For panel mounting, replace M4 screws by new one (not supplied)
with appropriate length to panel´s thickness.
Remarks
• VOUT is positive when IP flows in the direction of the arrow.
• The return busbar and primary conductor elbow must be located
at least at 2.5 x window length more far away from the transducer
case.
• The temperature of the primary busbar can not exceed 90 °C.
• Dynamic performances are the best with a primary busbar
completely filling the primary aperture.
• This is a standard model. For different versions (supply voltages,
different outputs, bidirectional measurements...), please
contact us.